Vigilon Compact ControlVigilon Compact analogue addressable 1-2 loop panels offer small to medium sized building owners the unique system functionality of Vigilon with the very best in control panel aesthetics – stainless steel door options are available to provide a discreet and luxurious feel in upmarket office environments. The introduction of innovative design features into this panel means that the wall space needed to mount the panel is now 60% smaller than a standard Vigilon installation. Vigilon Compact analogue addressable panels fully comply with EN54: Parts 2 & 4 and can be specified with 1 or 2 detection loops, each capable of accommodating up to 200 Vigilon devices including repeat panels, interfaces, manual call points and S-Quad sensor/sounder/strobes. Gent’s innovative new S-Quad is a combined multi-sensor range with speech, sounder and strobe in one intelligent unit. Fully compatible with Gent’s S-Cubed alarm devices (offering sound, speech or strobe effects in combination), Vigilon Compact also offers the familiar advantages of combined sensor-sounders and loop powered beam detection with integral short circuit isolators fitted into every loop device. Additional features - Vigilon’s powerful software allows the fire alarm system to be configured to meet the fire alarm needs of the building
- Combining the proven reliability of the Vigilon range of sensors and true analogue sensing keeps false alarms to a minimum
- Alarm sound levels can be increased by simply replacing a sensor with a sensor/sounder, saving costly additional wiring
- To meet the requirements of BS 5839-1: 2002 the Vigilon Compact is supplied with separate zonal indication, visible at access level 1. This comprises 32 fire LEDs (secret till lit) which enables ‘at a glance’ overview indication, without the need for manual intervention by fire fighters

Dimensions (mm) w 338 h 403 d 101 | Type | Control panel | | Loop Capacity | 200 | | Networking Capacity | Upto 32 panels | | Ingress Protection | IP31 | | Approx Weight | 16.6 Kg (with batteries) | | Operating Temperature | 0oC to +45oC | | Relevant Standards | EN54 Pt 2 & 4 | | Batteries | 2 x 12V @ 12 Ah | | Battery Standby | 24 Hours + 30 minutes alarm | | Supply Voltage | 216V – 253V 50Hz | | Power Consumption | 140 W | | Cable Entry | Top and rear knockins | | Auxiliary Contacts | Programmable to activate on Fire, Fault or Disablement. (1 x SPCO 1 x DPCO) | | Sounder Circuits | 2 circuits @ 250mA each | | Monitored input | 1 input which is programmable to perform a logical action via a command build | | Communication ports | 2 x RS485, 1 x RS232 selectable functions | | Approvals Pending | LPCB | |
|
See the Vigilon Control Panel |